DTC TROUBLESHOOTING

DTC INDICATOR 2 : HVAC CONTROL UNIT INTERNAL ERROR

1. Problem verification:

  1. Clear the history DTCs.
  2. Do the Self-Diagnostic Function.
  3. Checking for DTCs.

Does the RECIRCULATION indicator blink twice?

YES

Replace the HVAC control unit.

NO

Intermittent failure, the system is OK at this time.

DTC INDICATOR 3 A PROBLEM IN THE RECIRCULATION CONTROL MOTOR CIRCUIT, LINKAGE, DOOR, OR MOTOR

1. Problem verification:

  1. Clear the history DTCs.
  2. Do the Self-Diagnostic Function.
  3. Checking for DTCs.

Does the RECIRCULATION indicator blink twice?

YES

Replace the HVAC control unit.

NO

Intermittent failure, the system is OK at this time.

DTC INDICATOR 3 A PROBLEM IN THE RECIRCULATION CONTROL MOTOR CIRCUIT, LINKAGE, DOOR, OR MOTOR

1. Problem verification:

  1. Clear the history DTCs.
  2. Do the Self-Diagnostic Function.
  3. Checking for DTCs.

Does the RECIRCULATION indicator blink three times?

YES

Go to step 2.

NO

Intermittent failure. Check for loose wires or poor connections on the recirculation control motor circuit.

2. Open wire check (F/R MTR(REC)/M-REC line):

  1. Turn the vehicle to the OFF (LOCK) mode.

    READ NEXT:

     HVAC System - Testing & Troubleshooting

     Inspection & Adjustment

    A/C SYSTEM CONTAMINATION INSPECTION Inspection NOTE: If the A/C compressor failure is diagnosed, always use this inspection to check the extent of contamination in the A/C system. The parts illu

     Description

    SEE MORE:

     Final Drive Shaft Tapered Roller Bearing Outer Race Replacement (CVT)

    Special Tools Required Driver Handle, 40 mm I.D. 07746-0030100 Replacement NOTE: The tapered roller bearing and the tapered roller bearing outer race should be replaced as a set. Adjust the tapered roller bearing preload after replacing the tapered roller bearing and the tapered roller bea

     A/C Diagnostic Process

    When a customer presents an A/C concern, do the following procedure to identify the cause of the problem. 1. Confirm the type of concern. If a customer complains about an A/C performance problem, go to step 2. If a customer complains about an A/C noise problem, do the A/C system noise check.